Naoyuki Shono, Brian Ninni, Franklin King, Takahisa Kato, Junichi Tokuda, Takahiro Fujimoto, Kemal Tuncali, and Nobuhiko Hata. 6/2020. “Simulated Accuracy Assessment of Small Footprint Body-mounted Probe Alignment Device for MRI-guided Cryotherapy of Abdominal Lesions.” Med Phys, 47, 6, Pp. 2337-49.Abstract
PURPOSE: Magnetic resonance imaging (MRI)-guided percutaneous cryotherapy of abdominal lesions, an established procedure, uses MRI to guide and monitor the cryoablation of lesions. Methods to precisely guide cryotherapy probes with a minimum amount of trial-and-error are yet to be established. To aid physicians in attaining precise probe alignment without trial-and-error, a body-mounted motorized cryotherapy-probe alignment device (BMCPAD) with motion compensation was clinically tested in this study. The study also compared the contribution of body motion and organ motion compensation to the guidance accuracy of a body-mounted probe alignment device. METHODS: The accuracy of guidance using the BMCPAD was prospectively measured during MRI-guided percutaneous cryotherapies before insertion of the probes. Clinical parameters including patient age, types of anesthesia, depths of the target, and organ sites of target were collected. By using MR images of the target organs and fiducial markers embedded in the BMCPAD, we retrospectively simulated the guidance accuracy with body motion compensation, organ motion compensation, and no compensation. The collected data were analyzed to test the impact of motion compensation on the guidance accuracy. RESULTS: Thirty-seven physical guidance of probes were prospectively recorded for sixteen completed cases. The accuracy of physical guidance using the BMCPAD was 13.4 ± 11.1 mm. The simulated accuracy of guidance with body motion compensation, organ motion compensation, and no compensation was 2.4 ± 2.9 mm, 2.2 ± 1.6 mm, and 3.5 ± 2.9 mm, respectively. Data analysis revealed that the body motion compensation and organ motion compensation individually impacted the improvement in the accuracy of simulated guidance. Moreover, the difference in the accuracy of guidance either by body motion compensation or organ motion compensation was not statistically significant. The major clinical parameters impacting the accuracy of guidance were the body and organ motions. Patient age, types of anesthesia, depths of the target, and organ sites of target did not influence the accuracy of guidance using BMCPAD. The magnitude of body surface movement and organ movement exhibited mutual statistical correlation. CONCLUSIONS: The BMCPAD demonstrated guidance accuracy comparable to that of previously reported devices for CT-guided procedures. The analysis using simulated motion compensation revealed that body motion compensation and organ motion compensation individually impact the improvement in the accuracy of device-guided cryotherapy probe alignment. Considering the correlation between body and organ movements, we also determined that body motion compensation using the ring fiducial markers in the BMCPAD can be solely used to address both body and organ motions in MRI-guided cryotherapy.
Junichi Tokuda, Qun Wang, Kemal Tuncali, Ravi T Seethamraju, Clare M Tempany, and Ehud J Schmidt. 5/2020. “Temperature-Sensitive Frozen-Tissue Imaging for Cryoablation Monitoring Using STIR-UTE MRI.” Invest Radiol, 55, 5, Pp. 310-7.Abstract
PURPOSE: The aim of this study was to develop a method to delineate the lethally frozen-tissue region (temperature less than -40°C) arising from interventional cryoablation procedures using a short tau inversion-recovery ultrashort echo-time (STIR-UTE) magnetic resonance (MR) imaging sequence. This method could serve as an intraprocedural validation of the completion of tumor ablation, reducing the number of local recurrences after cryoablation procedures. MATERIALS AND METHODS: The method relies on the short T1 and T2* relaxation times of frozen soft tissue. Pointwise Encoding Time with Radial Acquisition, a 3-dimensional UTE sequence with TE = 70 microseconds, was optimized with STIR to null tissues with a T1 of approximately 271 milliseconds, the threshold T1. Because the T1 relaxation time of frozen tissue in the temperature range of -40°C < temperature < -8°C is shorter than the threshold T1 at the 3-tesla magnetic field, tissues in this range should appear hyperintense. The sequence was evaluated in ex vivo frozen tissue, where image intensity and actual tissue temperatures, measured by thermocouples, were correlated. Thereafter, the sequence was evaluated clinically in 12 MR-guided prostate cancer cryoablations, where MR-compatible cryoprobes were used to destroy cancerous tissue and preserve surrounding normal tissue. RESULTS: The ex vivo experiment using a bovine muscle demonstrated that STIR-UTE images showed regions approximately between -40°C and -8°C as hyperintense, with tissues at lower and higher temperatures appearing dark, making it possible to identify the region likely to be above the lethal temperature inside the frozen tissue. In the clinical cases, the STIR-UTE images showed a dark volume centered on the cryoprobe shaft, Vinner, where the temperature is likely below -40°C, surrounded by a doughnut-shaped hyperintense volume, where the temperature is likely between -40°C and -8°C. The hyperintense region was itself surrounded by a dark volume, where the temperature is likely above -8°C, permitting calculation of Vouter. The STIR-UTE frozen-tissue volumes, Vinner and Vouter, appeared significantly smaller than signal voids on turbo spin echo images (P < 1.0 × 10), which are currently used to quantify the frozen-tissue volume ("the iceball"). The ratios of the Vinner and Vouter volumes to the iceball were 0.92 ± 0.08 and 0.29 ± 0.07, respectively. In a single postablation follow-up case, a strong correlation was seen between Vinner and the necrotic volume. CONCLUSIONS: Short tau inversion-recovery ultrashort echo-time MR imaging successfully delineated the area approximately between -40°C and -8°C isotherms in the frozen tissue, demonstrating its potential to monitor the lethal ablation volume during MR-guided cryoablation.
Atsushi Yamada, Junichi Tokuda, Shigeyuki Naka, Koichiro Murakami, Tohru Tani, and Shigehiro Morikawa. 3/2020. “Magnetic Resonance and Ultrasound Image-guided Navigation System using a Needle Manipulator.” Med Phys, 47, 3, Pp. 850-8.Abstract
PURPOSE: Image guidance is crucial for percutaneous tumor ablations, enabling accurate needle-like applicator placement into target tumors while avoiding tissues that are sensitive to injury and/or correcting needle deflection. Although ultrasound (US) is widely used for image guidance, magnetic resonance (MR) is preferable due to its superior soft tissue contrast. The objective of this study was to develop and evaluate an MR and US multi-modal image-guided navigation system with a needle manipulator to enable US-guided applicator placement during MR imaging (MRI)-guided percutaneous tumor ablation. METHODS: The MRI-compatible needle manipulator with US probe was installed adjacent to a 3 Tesla MRI scanner patient table. Coordinate systems for the MR image, patient table, manipulator, and US probe were all registered using an optical tracking sensor. The patient was initially scanned in the MRI scanner bore for planning and then moved outside the bore for treatment. Needle insertion was guided by real-time US imaging fused with the reformatted static MR image to enhance soft tissue contrast. Feasibility, targeting accuracy, and MR compatibility of the system were evaluated using a bovine liver and agar phantoms. RESULTS: Targeting error for 50 needle insertions was 1.6 ± 0.6 mm (mean ± standard deviation). The experiment confirmed that fused MR and US images provided real-time needle localization against static MR images with soft tissue contrast. CONCLUSIONS: The proposed MR and US multi-modal image-guided navigation system using a needle manipulator enabled accurate needle insertion by taking advantage of static MR and real-time US images simultaneously. Real-time visualization helped determine needle depth, tissue monitoring surrounding the needle path, target organ shifts, and needle deviation from the path.
Yuanqian Gao, Kiyoshi Takagi, Takahisa Kato, Naoyuki Shono, and Nobuhiko Hata. 2/2020. “Continuum Robot With Follow-the-Leader Motion for Endoscopic Third Ventriculostomy and Tumor Biopsy.” IEEE Trans Biomed Eng, 67, 2, Pp. 379-90.Abstract
BACKGROUND: In a combined endoscopic third ventriculostomy (ETV) and endoscopic tumor biopsy (ETB) procedure, an optimal tool trajectory is mandatory to minimize trauma to surrounding cerebral tissue. OBJECTIVE: This paper presents wire-driven multi-section robot with push-pull wire. The robot is tested to attain follow-the-leader (FTL) motion to place surgical instruments through narrow passages while minimizing the trauma to tissues. METHODS: A wire-driven continuum robot with six sub-sections was developed and its kinematic model was proposed to achieve FTL motion. An accuracy test to assess the robot's ability to attain FTL motion along a set of elementary curved trajectory was performed. We also used hydrocephalus ventricular model created from human subject data to generate five ETV/ETB trajectories and conducted a study assessing the accuracy of the FTL motion along these clinically desirable trajectories. RESULTS: In the test with elementary curved paths, the maximal deviation of the robot was increased from 0.47 mm at 30 turn to 1.78 mm at 180 in a simple C-shaped curve. S-shaped FTL motion had lesser deviation ranging from 0.16 to 0.18 mm. In the phantom study, the greatest tip deviation was 1.45 mm, and the greatest path deviation was 1.23 mm. CONCLUSION: We present the application of a continuum robot with FTL motion to perform a combined ETV/ETB procedure. The validation study using human subject data indicated that the accuracy of FTL motion is relatively high. The study indicated that FTL motion may be useful tool for combined ETV and ETB.
2019
JP Guenette, N Ben-Shlomo, J Jayender, RT Seethamraju, V Kimbrell, N-A Tran, RY Huang, CJ Kim, JI Kass, CE Corrales, and TC Lee. 2019. “MR Imaging of the Extracranial Facial Nerve with the CISS Sequence.” AJNR Am J Neuroradiol, 40, 11, Pp. 1954-9.Abstract
BACKGROUND AND PURPOSE: MR imaging is not routinely used to image the extracranial facial nerve. The purpose of this study was to determine the extent to which this nerve can be visualized with a CISS sequence and to determine the feasibility of using that sequence for locating the nerve relative to tumor. MATERIALS AND METHODS: Thirty-two facial nerves in 16 healthy subjects and 4 facial nerves in 4 subjects with parotid gland tumors were imaged with an axial CISS sequence protocol that included 0.8-mm isotropic voxels on a 3T MR imaging system with a 64-channel head/neck coil. Four observers independently segmented the 32 healthy subject nerves. Segmentations were compared by calculating average Hausdorff distance values and Dice similarity coefficients. RESULTS: The primary bifurcation of the extracranial facial nerve into the superior temporofacial and inferior cervicofacial trunks was visible on all 128 segmentations. The mean of the average Hausdorff distances was 1.2 mm (range, 0.3-4.6 mm). Dice coefficients ranged from 0.40 to 0.82. The relative position of the facial nerve to the tumor could be inferred in all 4 tumor cases. CONCLUSIONS: The facial nerve can be seen on CISS images from the stylomastoid foramen to the temporofacial and cervicofacial trunks, proximal to the parotid plexus. Use of a CISS protocol is feasible in the clinical setting to determine the location of the facial nerve relative to tumor.
Haoyin Zhou, Tao Zhang, and Jayender Jagadeesan. 2019. “Re-weighting and 1-Point RANSAC-Based P nP Solution to Handle Outliers.” IEEE Trans Pattern Anal Mach Intell, 41, 12, Pp. 3022-33.Abstract
The ability to handle outliers is essential for performing the perspective- n-point (P nP) approach in practical applications, but conventional RANSAC+P3P or P4P methods have high time complexities. We propose a fast P nP solution named R1PP nP to handle outliers by utilizing a soft re-weighting mechanism and the 1-point RANSAC scheme. We first present a P nP algorithm, which serves as the core of R1PP nP, for solving the P nP problem in outlier-free situations. The core algorithm is an optimal process minimizing an objective function conducted with a random control point. Then, to reduce the impact of outliers, we propose a reprojection error-based re-weighting method and integrate it into the core algorithm. Finally, we employ the 1-point RANSAC scheme to try different control points. Experiments with synthetic and real-world data demonstrate that R1PP nP is faster than RANSAC+P3P or P4P methods especially when the percentage of outliers is large, and is accurate. Besides, comparisons with outlier-free synthetic data show that R1PP nP is among the most accurate and fast P nP solutions, which usually serve as the final refinement step of RANSAC+P3P or P4P. Compared with REPP nP, which is the state-of-the-art P nP algorithm with an explicit outliers-handling mechanism, R1PP nP is slower but does not suffer from the percentage of outliers limitation as REPP nP.
2018
Marek Wartenberg, Joseph Schornak, Katie Gandomi, Paulo Carvalho, Chris Nycz, Niravkumar Patel, Iulian Iordachita, Clare Tempany, Nobuhiko Hata, Junichi Tokuda, and Gregory S. Fischer. 2018. “Closed-Loop Active Compensation for Needle Deflection and Target Shift During Cooperatively Controlled Robotic Needle Insertion.” Ann Biomed Eng, 46, 10, Pp. 1582-94.Abstract
Intra-operative imaging is sometimes available to assist needle biopsy, but typical open-loop insertion does not account for unmodeled needle deflection or target shift. Closed-loop image-guided compensation for deviation from an initial straight-line trajectory through rotational control of an asymmetric tip can reduce targeting error. Incorporating robotic closed-loop control often reduces physician interaction with the patient, but by pairing closed-loop trajectory compensation with hands-on cooperatively controlled insertion, a physician's control of the procedure can be maintained while incorporating benefits of robotic accuracy. A series of needle insertions were performed with a typical 18G needle using closed-loop active compensation under both fully autonomous and user-directed cooperative control. We demonstrated equivalent improvement in accuracy while maintaining physician-in-the-loop control with no statistically significant difference (p > 0.05) in the targeting accuracy between any pair of autonomous or individual cooperative sets, with average targeting accuracy of 3.56 mm. With cooperatively controlled insertions and target shift between 1 and 10 mm introduced upon needle contact, the system was able to effectively compensate up to the point where error approached a maximum curvature governed by bending mechanics. These results show closed-loop active compensation can enhance targeting accuracy, and that the improvement can be maintained under user directed cooperative insertion.
Pedro Moreira, Niravkumar Patel, Marek Wartenberg, Gang Li, Kemal Tuncali, Tamas Heffter, Everette C Burdette, Iulian Iordachita, Gregory S. Fischer, Nobuhiko Hata, Clare MC Tempany, and Junichi Tokuda. 2018. “Evaluation of Robot-assisted MRI-guided Prostate Biopsy: Needle Path Analysis during Clinical Trials.” Phys Med Biol, 63, 20, Pp. 20NT02.Abstract
PURPOSE: While the interaction between a needle and the surrounding tissue is known to cause a significant targeting error in prostate biopsy leading to false-negative results, few studies have demonstrated how it impacts in the actual procedure. We performed a pilot study on robot-assisted MRI-guided prostate biopsy with an emphasis on the in-depth analysis of the needle-tissue interaction in-vivo. Methods: The data were acquired during in-bore transperineal prostate biopsies in patients using a 4 degrees-of-freedom (DoF) MRI-compatible robot. The anatomical structures in the pelvic area and the needle path were reconstructed from MR images, and quantitatively analyzed. We analyzed each structure individually and also proposed a mathematical model to investigate the influence of those structures in the targeting error using the mixed-model regression. Results: The median targeting error in 188 insertions (27 patients) was 6.3mm. Both the individual anatomical structure analysis and the mixed-model analysis showed that the deviation resulted from the contact between the needle and the skin as the main source of error. On contrary, needle bending inside the tissue (expressed as needle curvature) did not vary among insertions with targeting errors above and below the average. The analysis indicated that insertions crossing the bulbospongiosus presented a targeting error lower than the average. The mixed-model analysis demonstrated that the distance between the needle guide and the patient skin, the deviation at the entry point, and the path length inside the pelvic diaphragm had a statistically significant contribution to the targeting error (p<0.05). Conclusions: Our results indicate that the errors associated with the elastic contact between the needle and the skin were more prominent than the needle bending along the insertion. Our findings will help to improve the preoperative planning of transperineal prostate biopsies.
Baichuan Jiang, Wenpeng Gao, Daniel Kacher, Erez Nevo, Barry Fetics, Thomas C Lee, and Jagadeesan Jayender. 2018. “Kalman Filter-based EM-optical Sensor Fusion for Needle Deflection Estimation.” Int J Comput Assist Radiol Surg, 13, 4, Pp. 573-83.Abstract
PURPOSE: In many clinical procedures such as cryoablation that involves needle insertion, accurate placement of the needle's tip at the desired target is the major issue for optimizing the treatment and minimizing damage to the neighboring anatomy. However, due to the interaction force between the needle and tissue, considerable error in intraoperative tracking of the needle tip can be observed as needle deflects. METHODS: In this paper, measurements data from an optical sensor at the needle base and a magnetic resonance (MR) gradient field-driven electromagnetic (EM) sensor placed 10 cm from the needle tip are used within a model-integrated Kalman filter-based sensor fusion scheme. Bending model-based estimations and EM-based direct estimation are used as the measurement vectors in the Kalman filter, thus establishing an online estimation approach. RESULTS: Static tip bending experiments show that the fusion method can reduce the mean error of the tip position estimation from 29.23 mm of the optical sensor-based approach to 3.15 mm of the fusion-based approach and from 39.96 to 6.90 mm, at the MRI isocenter and the MRI entrance, respectively. CONCLUSION: This work established a novel sensor fusion scheme that incorporates model information, which enables real-time tracking of needle deflection with MRI compatibility, in a free-hand operating setup.
JP Guenette, RT Seethamraju, J Jayender, CE Corrales, and TC Lee. 2018. “MR Imaging of the Facial Nerve through the Temporal Bone at 3T with a Noncontrast Ultrashort Echo Time Sequence.” AJNR Am J Neuroradiol, 39, 10, Pp. 1903-6.Abstract
The pointwise encoding time reduction with radial acquisition (PETRA) ultrashort echo time MR imaging sequence at 3T enables visualization of the facial nerve from the brain stem, through the temporal bone, to the stylomastoid foramen without intravenous contrast. Use of the PETRA sequence, or other ultrashort echo time sequences, should be considered in the MR imaging evaluation of certain skull base tumors and perhaps other facial nerve and temporal bone pathologies.
Ehud J Schmidt and Henry R Halperin. 2018. “MRI use for Atrial Tissue Characterization in Arrhythmias and for EP Procedure Guidance.” Int J Cardiovasc Imaging, 34, 1, Pp. 81-95.Abstract
We review the utilization of magnetic resonance imaging methods for classifying atrial tissue properties that act as a substrate for common cardiac arrhythmias, such as atrial fibrillation. We then review state-of-the-art methods for mapping this substrate as a predicate for treatment, as well as methods used to ablate the electrical pathways that cause arrhythmia and restore patients to sinus rhythm.
Wenpeng Gao, Baichuan Jiang, Daniel F Kacher, Barry Fetics, Erez Nevo, Thomas C Lee, and Jagadeesan Jayender. 2018. “Real-time Probe Tracking using EM-optical Sensor for MRI-guided Cryoablation .” Int J Med Robot, 14, 1.Abstract
BACKGROUND: A method of real-time, accurate probe tracking at the entrance of the MRI bore is developed, which, fused with pre-procedural MR images, will enable clinicians to perform cryoablation efficiently in a large workspace with image guidance. METHODS: Electromagnetic (EM) tracking coupled with optical tracking is used to track the probe. EM tracking is achieved with an MRI-safe EM sensor working under the scanner's magnetic field to compensate the line-of-sight issue of optical tracking. Unscented Kalman filter-based probe tracking is developed to smooth the EM sensor measurements when occlusion occurs and to improve the tracking accuracy by fusing the measurements of two sensors. RESULTS: Experiments with a spine phantom show that the mean targeting errors using the EM sensor alone and using the proposed method are 2.21 mm and 1.80 mm, respectively. CONCLUSION: The proposed method achieves more accurate probe tracking than using an EM sensor alone at the MRI scanner entrance.
Momen Abayazid, Takahisa Kato, Stuart G Silverman, and Nobuhiko Hata. 2018. “Using Needle Orientation Sensing as Surrogate Signal for Respiratory Motion Estimation in Rercutaneous Interventions.” Int J Comput Assist Radiol Surg, 13, 1, Pp. 125-33.Abstract
PURPOSE: To develop and evaluate an approach to estimate the respiratory-induced motion of lesions in the chest and abdomen. MATERIALS AND METHODS: The proposed approach uses the motion of an initial reference needle inserted into a moving organ to estimate the lesion (target) displacement that is caused by respiration. The needles position is measured using an inertial measurement unit (IMU) sensor externally attached to the hub of an initially placed reference needle. Data obtained from the IMU sensor and the target motion are used to train a learning-based approach to estimate the position of the moving target. An experimental platform was designed to mimic respiratory motion of the liver. Liver motion profiles of human subjects provided inputs to the experimental platform. Variables including the insertion angle, target depth, target motion velocity and target proximity to the reference needle were evaluated by measuring the error of the estimated target position and processing time. RESULTS: The mean error of estimation of the target position ranged between 0.86 and 1.29 mm. The processing maximum training and testing time was 5 ms which is suitable for real-time target motion estimation using the needle position sensor. CONCLUSION: The external motion of an initially placed reference needle inserted into a moving organ can be used as a surrogate, measurable and accessible signal to estimate in real-time the position of a moving target caused by respiration; this technique could then be used to guide the placement of subsequently inserted needles directly into the target.
2017
PB Shyn, S Tremblay-Paquet, K Palmer, S Tatli, K Tuncali, OI Olubiyi, N Hata, and SG Silverman. 2017. “Breath-hold PET/CT-guided Tumor Ablation under General Anesthesia: Accuracy of Tumor Image Registration and Projected Ablation Zone Overlap.” Clin Radiol, 72, 3, Pp. 223-9.Abstract

AIM: To assess single-breath-hold combined positron-emission tomography/computed tomography (PET/CT) for accuracy of tumour image registration and projected ablation volume overlap in patients undergoing percutaneous PET/CT-guided tumour-ablation procedures under general anaesthesia. MATERIALS AND METHODS: Eight patients underwent 12 PET/CT-guided tumour-ablation procedures to treat 20 tumours in the lung, liver, or adrenal gland. Using breath-hold PET/CT, the centre of the tumour was marked on each PET and CT acquisition by four readers to assess two- (2D) and three-dimensional (3D) spatial misregistration. Overlap of PET and CT projected ablation volumes were compared using the Dice similarity coefficient (DSC). Interobserver differences were assessed with repeated measure analysis of variance (ANOVA). Technical success and local progression rates were noted. RESULTS: Mean tumour 2D PET/CT misregistrations were 1.02 mm (range 0.01-5.02), 1.89 (0.03-7.85), and 3.05 (0-10) in the x, y, and z planes. Mean 3D misregistration was 4.4 mm (0.36-10.74). Mean projected PET/CT ablation volume DSC was 0.72 (±0.19). No significant interobserver differences in 3D misregistration (p=0.73) or DSC (p=0.54) were observed. Technical success of ablations was 100%; one (5.3%) of 19 tumours progressed. CONCLUSION: Accurate spatial registration of tumours and substantial overlap of projected ablation volumes are achievable when comparing PET and CT acquisitions from single-breath-hold PET/CT. The results suggest that tumours visible only at PET could be accurately targeted and ablated using this technique.

Ming Li, Vivek Narayan, Ritu R Gill, Jyothi P Jagannathan, Maria F Barile, Feng Gao, Raphael Bueno, and Jagadeesan Jayender. 2017. “Computer-Aided Diagnosis of Ground-Glass Opacity Nodules Using Open-Source Software for Quantifying Tumor Heterogeneity.” AJR Am J Roentgenol, 209, 6, Pp. 1216-27.Abstract
OBJECTIVE: The purposes of this study are to develop quantitative imaging biomarkers obtained from high-resolution CTs for classifying ground-glass nodules (GGNs) into atypical adenomatous hyperplasia (AAH), adenocarcinoma in situ (AIS), minimally invasive adenocarcinoma (MIA), and invasive adenocarcinoma (IAC); to evaluate the utility of contrast enhancement for differential diagnosis; and to develop and validate a support vector machine (SVM) to predict the GGN type. MATERIALS AND METHODS: The heterogeneity of 248 GGNs was quantified using custom software. Statistical analysis with a univariate Kruskal-Wallis test was performed to evaluate metrics for significant differences among the four GGN groups. The heterogeneity metrics were used to train a SVM to learn and predict the lesion type. RESULTS: Fifty of 57 and 51 of 57 heterogeneity metrics showed statistically significant differences among the four GGN groups on unenhanced and contrast-enhanced CT scans, respectively. The SVM predicted lesion type with greater accuracy than did three expert radiologists. The accuracy of classifying the GGNs into the four groups on the basis of the SVM algorithm was 70.9%, whereas the accuracy of the radiologists was 39.6%. The accuracy of SVM in classifying the AIS and MIA nodules was 73.1%, and the accuracy of the radiologists was 35.7%. For indolent versus invasive lesions, the accuracy of the SVM was 88.1%, and the accuracy of the radiologists was 60.8%. We found that contrast enhancement does not significantly improve the differential diagnosis of GGNs. CONCLUSION: Compared with the GGN classification done by the three radiologists, the SVM trained regarding all the heterogeneity metrics showed significantly higher accuracy in classifying the lesions into the four groups, differentiating between AIS and MIA and between indolent and invasive lesions. Contrast enhancement did not improve the differential diagnosis of GGNs.
Melissa A Mallory, Yasuaki Sagara, Fatih Aydogan, Stephen Desantis, Jagadeesan Jayender, Diana Caragacianu, Eva Gombos, Kirby G. Vosburgh, Ferenc A Jolesz, and Mehra Golshan. 2017. “Feasibility of Intraoperative Breast MRI and the Role of Prone Versus Supine Positioning in Surgical Planning for Breast-Conserving Surgery.” Breast J, 23, 6, Pp. 713-7.Abstract
We assessed the feasibility of supine intraoperative MRI (iMRI) during breast-conserving surgery (BCS), enrolling 15 patients in our phase I trial between 2012 and 2014. Patients received diagnostic prone MRI, BCS, pre-excisional supine iMRI, and postexcisional supine iMRI. Feasibility was assessed based on safety, sterility, duration, and image-quality. Twelve patients completed the study; mean duration = 114 minutes; all images were adequate; no complications, safety, or sterility issues were encountered. Substantial tumor-associated changes occurred (mean displacement = 67.7 mm, prone-supine metric, n = 7). We have demonstrated iMRI feasibility for BCS and have identified potential limitations of prone breast MRI that may impact surgical planning.
2016
Ehud J Schmidt, Ronald D Watkins, Menekhem M Zviman, Michael A Guttman, Wei Wang, and Henry A Halperin. 2016. “A Magnetic Resonance Imaging–Conditional External Cardiac De brillator for Resuscitation within the Magnetic Resonance Imaging Scanner Bore.” Circ Cardiovasc Imaging., 9, Pp. e005091.Abstract

Subjects undergoing cardiac arrest within a magnetic resonance imaging (MRI) scanner are currently removed from the bore and then from the MRI suite, before the delivery of cardiopulmonary resuscitation and de brillation, potentially increasing the risk of mortality. This precludes many higher-risk (acute ischemic and acute stroke) patients from undergoing MRI and MRI-guided intervention. An MRI-conditional cardiac de brillator should enable scanning with de brillation pads attached and the generator ON, enabling application of de brillation within the seconds of MRI after a cardiac event. An MRI-conditional external de brillator may improve patient acceptance for MRI procedures. Methods and Results—A commercial external de brillator was rendered 1.5 Tesla MRI-conditional by the addition of novel radiofrequency lters between the generator and commercial disposable surface pads. The radiofrequency lters reduced emission into the MRI scanner and prevented cable/surface pad heating during imaging, while preserving all the de brillator monitoring and delivery functions. Human volunteers were imaged using high speci c absorption rate sequences to validate MRI image quality and lack of heating. Swine were electrically brillated (n=4) and thereafter de brillated both outside and inside the MRI bore. MRI image quality was reduced by 0.8 or 1.6 dB, with the generator in monitoring mode and operating on battery or AC power, respectively. Commercial surface pads did not create artifacts deeper than 6 mm below the skin surface. Radiofrequency heating was within US Food and Drug Administration guidelines. De brillation was completely successful inside and outside the MRI bore. Conclusions—A prototype MRI-conditional de brillation system successfully de brillated in the MRI without degrading the image quality or increasing the time needed for de brillation. It can increase patient acceptance for MRI procedures.

Soichiro Tani, Servet Tatli, Nobuhiko Hata, Xavier Garcia-Rojas, Olutayo I Olubiyi, Stuart G Silverman, and Junichi Tokuda. 2016. “Three-dimensional Quantitative Assessment of Ablation Margins Based on Registration of Pre- and Post-procedural MRI and Distance Map.” Int J Comput Assist Radiol Surg, 11, 6, Pp. 1133-42.Abstract

PURPOSE: Contrast-enhanced MR images are widely used to confirm the adequacy of ablation margin after liver ablation for early prediction of local recurrence. However, quantitative assessment of the ablation margin by comparing pre- and post-procedural images remains challenging. We developed and tested a novel method for three-dimensional quantitative assessment of ablation margin based on non-rigid image registration and 3D distance map. METHODS: Our method was tested with pre- and post-procedural MR images acquired in 21 patients who underwent image-guided percutaneous liver ablation. The two images were co-registered using non-rigid intensity-based registration. After the tumor and ablation volumes were segmented, target volume coverage, percent of tumor coverage, and Dice similarity coefficient were calculated as metrics representing overall adequacy of ablation. In addition, 3D distance map around the tumor was computed and superimposed on the ablation volume to identify the area with insufficient margins. For patients with local recurrences, the follow-up images were registered to the post-procedural image. Three-dimensional minimum distance between the recurrence and the areas with insufficient margins was quantified. RESULTS: The percent tumor coverage for all nonrecurrent cases was 100 %. Five cases had tumor recurrences, and the 3D distance map revealed insufficient tumor coverage or a 0-mm margin. It also showed that two recurrences were remote to the insufficient margin. CONCLUSIONS: Non-rigid registration and 3D distance map allow us to quantitatively evaluate the adequacy of the ablation margin after percutaneous liver ablation. The method may be useful to predict local recurrences immediately following ablation procedure.

2015
Jagadeesan Jayender, Thomas C Lee, and Daniel T Ruan. 2015. “Real-Time Localization of Parathyroid Adenoma during Parathyroidectomy.” N Engl J Med, 373, 1, Pp. 96-8.